The Model 7400 Rim Type Panic Exit Device combines architectural elegance with heavy-duty security. Engineered for sleek, high-end commercial environments, this UL-listed device features an integrated, full-length push pad that eliminates visual clutter while ensuring compliance with life safety codes. Unlike vertical rod systems, the 7400 utilizes a rim-type surface strike mechanism, making it exceptionally reliable and versatile. It is suitable for storefront glass, aluminum-framed, hollow metal, and wood doors in high-traffic spaces such as retail centers, corporate offices, schools, and healthcare facilities.

Key Features

  • UL Listed with Deadlocking Latchbolt: Features an auxiliary deadlatch that interlocks when the door is closed, preventing external tampering or "looiding" (carding) while ensuring immediate egress from the inside.
  • Non-handed design: Can be installed on left or right-hand doors, reducing installation time and inventory complexity.
  • Narrow stile support: Compatible with 1-3/4” (45 mm) aluminum door stiles, ideal for storefront applications.
  • Durable construction: Extruded aluminum rail and push pad combined with die-cast zinc head and end caps.
  • Finish options: Anodized dark bronze or aluminum for coordination with modern architectural hardware.
  • Simple 45-Degree Dogging operation: Depress the touch bar, hold, and turn the flathead screwdriver 45 degrees clockwise to enable passage mode.

Technical Specifications

  • Device Length: Fits doors from 36” to 48” (Field-reversible and cuttable).
  • Door Thickness: 1-3/4” (45 mm) to 2” (50 mm).
  • Minimum Stile Width: 1-3/4” (45 mm) narrow stile aluminum.
  • Installation Height: Centerline of panic, latch, and strike sits at 39-17/32” (1014.1 mm) from the bottom of the door.
  • Latch Bolt Specification: UL Listed dead locking latch bolt to prevent forced entry.
  • Handing: Non-handed, completely field-reversible.
  • Dogging Operation: Engaged and released via a standard flathead screwdriver with a 45-degree turn.
  • Model 1062 Compatibility: Shares the exact same mounting footprint as Model 1062 for seamless retrofit.
  • Materials:
    • Rail / push pad: Extruded aluminum
    • Head / end caps: Die-cast zinc
  • Finishes: Anodized dark bronze or aluminum
  • Compliance: UL Listed panic exit devices
  • Set weight: 3 kg

Applications & Use Cases

  • Retail Storefront Entrances: Engineered for high-end retail environments requiring compliant panic exit devices that blend seamlessly with modern architectural glass design.
  • Commercial, Educational & Healthcare Facilities: An ideal solution for corporate offices, schools, and medical institutions needing consistent, safe, and code-compliant emergency egress.
  • Aluminum-Framed Glass & Mixed-Material Doors: Optimized for narrow stile aluminum doors, hollow metal doors, and wood door applications across diverse commercial layouts.
  • High-Traffic Service Doors: Built to withstand the rigorous demands of high-frequency daily operation in service corridors and main pedestrian pathways.
  • Model 1062 Retrofit & Retrofit Projects: Specially designed for buildings currently utilizing Model 1062. The identical mounting footprint allows for a rapid exterior aesthetic upgrade without modifying the existing door structure.

Entry & Accessory Options

  • Lever Trim: Available for entrance or passage functions, allowing controlled access from the exterior side of the door.
  • Rim Cylinder: Required for keyed entry functionality; compatible with standard commercial Rim cylinders.

Installation Overview

  1. Preparation: Verify door dimensions and determine the hand of the door. Mark the standard mounting height at 39-17/32” from the finished floor to the centerline of the latch and strike.
  2. Sizing: Measure the distance between the mounting holes on the lock and hinge stiles, then add 7/8” (22 mm) to determine the correct panic device length.
  3. Mounting: Secure the exit device body onto the stiles using the specified thread-cutting machine screws. If an external key cylinder is integrated, cylinder spindle must be inserted into coupling boss prior to fastening latch end on lock stile.
  4. Strike Alignment: Install the strike on the lock jamb centered on the latch. Adjust the alignment to reduce the distance between the latch and strike to zero, ensuring proper activation of the deadlatch mechanism.
  5. Final Test: Verify smooth egress function and set dogging by pressing the touch bar and turning the flathead screwdriver 45 degrees clockwise.

Operating Instructions

  • To Unlock Door Using Cylinder Key:
    Turn the key approximately 1/4 turn in either direction to retract the latch bolt and open the door. Return the key to the center position to remove. (NOTE: Exterior cylinder key WILL NOT dog the unit. Dogging must be performed from the inside via the end cover only.)
  • Dogging Using Flat-Head Screwdriver:
    Fully depress the touch bar and hold. Insert a standard flat-head screwdriver into the dogging hole located on the end cover and turn clockwise approximately 45 degrees to dog the device in the hold-open (passage) position.
  • To Release Dogging:
    Fully depress the touch bar and hold. Insert the flat-head screwdriver into the dogging hole and turn counterclockwise approximately 45 degrees. The touch bar will be released, and the latch bolt will re-engage for secure locking.

Packaging & Delivery

  • Origin: Taiwan
  • Lead time: 45 days after deposit
  • Packaging: 1 set per box; 4 boxes per carton
  • Included: Panic bar, screws pack, installation Templates, head and hinge end cover
  • Customized Packaging: Special packing or private labeling is available upon request.

Why Choose Model 7400

  • Elevate Project Aesthetics with Integrated Design: The 7400’s seamless, full-length push pad eliminates visual clutter and filler plates, creating the clean, premium architectural finish expected in modern high-end storefronts.
  • Universal Door Compatibility: A versatile solution that fits narrow stile aluminum, hollow metal, glass storefront, and solid wood doors.
  • Simplified Installation: The non-handed design eliminates the need for orientation checks, reducing installation time and on-site adjustments.
  • Built for Longevity: Extruded aluminum rail and durable anodized finishes ensure consistent performance in high-traffic commercial environments.
  • Certified Safety Standards: UL 305 compliance guarantees that your facility meets essential fire and safety building codes.
  • Seamless Model 1062 Retrofit: Shares the exact same mounting footprint as Model 1062 for an effortless aesthetic upgrade without re-drilling.

Buyer Considerations

  • Confirm Door Dimensions: Verify that the door width is between 36” and 48” and the door features a minimum narrow stile width of 1-3/4” (45 mm) to ensure compatibility with the device footprint.
  • Select the Appropriate Finish: Available in Anodized Dark Bronze or Aluminum to seamlessly match existing architectural hardware.
  • Evaluate Entry Requirements: Determine if the project requires an external lever trim or keyed cylinder for controlled access from the outside.
  • Verify Dogging Functionality: Ensure the 45-degree flathead screwdriver dogging feature aligns with operational needs. Note that the exterior cylinder key will not dog the unit.